• PENY X2H Çelik Hidrojen Element Analiz Cihazı satın al,PENY X2H Çelik Hidrojen Element Analiz Cihazı Fiyatlar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Markalar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Üretici,PENY X2H Çelik Hidrojen Element Analiz Cihazı Alıntılar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Şirket,
  • PENY X2H Çelik Hidrojen Element Analiz Cihazı satın al,PENY X2H Çelik Hidrojen Element Analiz Cihazı Fiyatlar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Markalar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Üretici,PENY X2H Çelik Hidrojen Element Analiz Cihazı Alıntılar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Şirket,
  • PENY X2H Çelik Hidrojen Element Analiz Cihazı satın al,PENY X2H Çelik Hidrojen Element Analiz Cihazı Fiyatlar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Markalar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Üretici,PENY X2H Çelik Hidrojen Element Analiz Cihazı Alıntılar,PENY X2H Çelik Hidrojen Element Analiz Cihazı Şirket,
PENY X2H Çelik Hidrojen Element Analiz Cihazı
  • Peny
  • Çin
  • 30 gün
  • Kaliteyi sağlayın ve zamanında teslim edin.

1. %0,00001–%0,2 arasında hidrojen analizi aralığını kapsar; titanyum ve alüminyum numuneleri için de özel aralıklar belirtilmiştir.
2. Hidrojen analizi sırasında ortam sıcaklığının etkisini azaltmak için sabit sıcaklık yalıtımlı termal iletkenlik yöntemini kullanır.
3. Genellikle entegre gaz doygunluk tespiti ve yüksek örnekleme frekansı sayesinde kararlı test verileri elde etmek için bir analizi yaklaşık 3 dakikada tamamlar.

Product Introduction

steel hydrogen analyzer


For laboratories analyzing hydrogen in steel and other inorganic solid materials, the challenge is not only detecting hydrogen within the required range. Routine testing also requires stable measurement conditions so that repeated analyses can be performed with consistent data. Changes in environmental temperature can interfere with the thermal conductivity cell, making temperature control an important consideration for laboratories that perform regular hydrogen analysis.

 

Our Solution:

The PENY X2H uses a thermal conductivity method with constant-temperature insulation in the thermal conductivity cell, helping reduce interference from environmental temperature changes. Its integrated gas saturation detector and high sampling frequency support stable data collection, while a typical analysis time of about 3 minutes helps laboratories handle routine testing efficiently. For research laboratories, the scalable software and open hardware upgrade capability also provide flexibility when future material-analysis requirements change.

 

Technical Specifications

ParametersSpecifications
Analysis RangeHydrogen:0.00001%~0.2%(Hydrogen in Titanium:1ppm~0.0350%;Hydrogen in aluminum lowest:0.1ppm)
Analysis TimeGenerally 3 minutes for steel hydrogen analyzer
Gas Way SystemComponents such as cylinders, gas way joints, air pipes, solenoid valves, etc. are imported products.
Carrier GasHigh purity argon gas(99.999%, 0.3~0.5mpa)
Power GasOrdinary nitrogen gas(Or purify compressed air0.3~0.5mpa)
Host Power SupplyAC200/220/230/240V ± 10%, frequency: 50/60 Hz ± 1Hz
Dimensions & WeightDimensions: 850×700×655mm [W x D x H], Weight:160kg, Fumigation-free wooden box.
Minimum Order Quantity1 unit
Payment Terms100% TT in advance
Mode of TransportationShipping by sea

 

Key Features

· Thermal conductivity detection for hydrogen elemental analysis.

· Constant-temperature insulation in the thermal conductivity cell helps reduce environmental-temperature interference.

· Integrated gas saturation detector with high sampling frequency for stable test data.

· Integrated instrument design with automated analysis operation.

· Scalable analysis software and open hardware upgrade capability for research and development needs.

 

Standard Configuration

· Host machine

· Analysis software

· Computer

· Electronic balance

Optional Configuration

· Regulated power supply

· Automatic cleaning system

· Water cooler

 

Why Consider the X2H for Procurement?

Routine testing: A typical analysis time of about 3 minutes can support repeated hydrogen testing workflows.

Measurement conditions: Constant-temperature insulation is designed to reduce the influence of environmental temperature changes on the thermal conductivity cell.

Research flexibility: Scalable software and open hardware upgrade capability can support later research projects and changing material-analysis requirements.

Production and delivery: Our factory can produce 20–30 analyzers per month, with a delivery period of 30 days.


About PENY

PENY is a high-tech enterprise specializing in the development and production of gas element analysis instruments, with 12 years of experience in designing and manufacturing elemental analyzers. Its predecessor, Shanghai Peny Optoelectronic Technology Co., Ltd., was established in 2014, and the production plant was relocated to the Information Valley Industrial Park in Nantong in 2023.

With a 2,100 m² production facility and a professional R&D and production team, PENY develops and manufactures elemental analysis instruments for applications involving metallic and non-metallic materials. The company has its own technical research team and supports multiple product categories within its production operation.

PENY has a production capacity of 20–30 analyzers per month and maintains equipment inventory to support timely delivery, including larger-volume orders. The standard delivery period is 30 days. Before leaving the factory, each instrument is checked and calibrated to help ensure proper operation.

The company states that it holds ISO 9001 certification, a trademark registration certificate, and a high-tech enterprise certificate. PENY also reports serving customers in 21+ countries, providing experience in supplying elemental analysis instruments to international markets. 

steel hydrogen elemental analyzer

hydrogen analyzer for steel

steel hydrogen analyzer

steel hydrogen elemental analyzer

hydrogen analyzer for steel

Customer Case Studies

ZhenTe New Material Technology Co., Ltd.

ZhenTe New Material Technology Co., Ltd. specializes in the research, development, and manufacturing of new materials and metal products, with strict requirements for testing and analysis. After visiting our factory and discussing their testing requirements with our team, they purchased our Carbon Sulfur Analyzer and ONH Analyzer. The analyzers have helped improve their testing efficiency and support more efficient production processes.

steel hydrogen analyzer

Benxi Iron and Steel Group

Founded in 1905, Benxi Iron and Steel Group is one of the long-established steel enterprises in China. The company required improved detection accuracy for carbon, sulfur, oxygen, nitrogen, and hydrogen elements in steel. After evaluating different options, Benxi Iron and Steel Group selected our Carbon Sulfur Analyzer and ONH Analyzer based on our technical experience, industry expertise, and product performance. The analyzers have been serving their testing needs since installation.

steel hydrogen elemental analyzer


FAQ

Q: What is the delivery time for the PENY X2H?
A: The standard delivery period is 30 days. PENY also maintains analyzer inventory and has a production capacity of 20–30 analyzers per month to support order requirements.

Q: What warranty does PENY provide for the X2H?
A: PENY provides a 1-year warranty for its analyzers.

Q: What after-sales service does PENY provide?
A: PENY provides 24/7 after-sales service to support customers during equipment use and operation.

Q: Does PENY provide training for X2H operators?
A: Evet. PENY, gerektiğinde video, telefon veya yerinde eğitim yoluyla müşteri eğitimi sağlayarak operatörlerin ekipmanın çalıştırılması ve kullanımı konusunda bilgi sahibi olmalarına yardımcı olabilir.

S: PENY yedek parça ve sarf malzemesi sağlayabilir mi?
A:Evet. PENY, uzun vadeli ekipman işletimi ve bakımı için element analiz cihazları için yedek parça ve sarf malzemeleri sağlamaktadır.

S: X2H'yi kurmadan önce ne gibi hazırlıklar yapılmalı?
A:Teslimattan önce kurulum ortamı ve kullanım gereksinimleri teyit edilmelidir. X2H, taşıyıcı gaz olarak 0,3–0,5 MPa basınçta %99,999 saflıkta argon, güç gazı olarak 0,3–0,5 MPa basınçta azot gazı veya saflaştırılmış basınçlı hava ve 200/220/230/240 V ±%10, 50/60 Hz ±1 Hz AC güç kaynağı gerektirir. Alıcılar, kurulumdan önce PENY ile detaylı kurulum gereksinimlerini teyit edebilirler.

S: PENY hangi uyumluluk ve dokümantasyon hizmetlerini sağlayabilir?
A:PENY, ISO 9001 sertifikasına, marka tescil belgesine ve yüksek teknoloji işletmesi sertifikasına sahiptir. Ekipman dokümantasyonu, fabrika denetim raporları, paketleme listeleri, kullanım kılavuzları, kalibrasyon sertifikaları ve diğer ek belgeleri içerebilir. Hedef ülkeye özgü ürün sertifikasyonu veya uyumluluk gereksinimleri için, alıcılar sipariş vermeden önce PENY ile gerekli belgeleri teyit etmelidir.

Son fiyat olsun? En kısa sürede cevap vereceğiz (12 saat içinde)

Gizlilik Politikası

close left right